1. 1000Ω
2. 10kΩ
3. 5kΩ
4. 1kΩ
5kΩ
1. The meter will burn out
2. The measurement will be too high
3. An inadmissably high current will flow
4. There will be almost no current in the circuit
There will be almost no current in the circuit
1. Electrodynamometer
2. PMNIC
3. Electrostatic
4. Moving iron
Electrostatic
1. 2.5 sec
2. 1.25 sec
3. 1.575 sec
4. 32 sec
1.575 sec
1. 9.9kΩ and 40kΩ
2. 10kΩ and 50kΩ
3. 20kΩ and 30kΩ
4. 200kΩ and 250kΩ
9.9kΩ and 40kΩ
1. 14.2 kHz
2. 13 .29 kHz
3. 10 kHz
4. none of the above
13 .29 kHz
1. both the wattmeter will indicated the same value but with opposite signs
2. both the wattmeter will indicate zero
3. both the wattmeter will indicate the sane value with same sign
4. one wattmeter will indicate zero and the other will indicate Some non-zero value
both the wattmeter will indicated the same value but with opposite signs
1. 10.01 kV/ s
2. 9.01 kV/ s
3. 12.2 kV sec
4. 2.0 kV/s
9.01 kV/ s
1. 13.04 % slow
2. 13.04 % fast
3. 15 % slow
4. 15 % fast
15 \% slow
1. 5 A
2. 10 A
3. 20 A
4. 50 A
20 A